TIC T-16A DME Pulse Generator Tel Intrrument Electronics 16B Aviation Avionics
- Zustand : Kaputt/zum Ausschlachten
- Versand : 3 Tage
- Marke : TIC
- ID# : 199279005
- Menge : 1 Artikel
- Besucherzahl : 623
- Ort : USA
- Verkäufer : bizsurplus (+90)
- Barcode : Keine
- Beginn : Do 21 Okt 2021 04:54:01 (CEST)
- Ende : Läuft-bis-verkauft
- Verbleibend : Läuft-bis-verkauft
Andere: Siehe Beschreibung
Auslandsversand nach Deutschland
von 1 Artikel(n) ändern

USPS Priority Mail Intl 24lb 0oz = US$186.25 (159,13€)
US$5.00 (4,27€) Bearbeitungsgebühr enthalten.
USPS Priority Mail Express Intl 24lb 0oz = US$215.90 (184,46€)
US$5.00 (4,27€) Bearbeitungsgebühr enthalten.
US$5.00 (4,27€) Bearbeitungsgebühr enthalten.
USPS Priority Mail Express Intl 24lb 0oz = US$215.90 (184,46€)
US$5.00 (4,27€) Bearbeitungsgebühr enthalten.
Versandkostenrechner
Beschreibung (Anbieter)
| |
TIC T-16A DME Pulse Generator Tel Intrrument Electronics
Includes power cord!!
The Tel-Instrument Electronics Corporation Type T-16A DME Pulse Generator is designed to produce reply pulses which simulate the DME portion of the VORTAC ground station. The T-16A is designed to be used with such signal generators as the Hewlett-Packard 612A and the 8925A DME/ ATC Test Set, or preferably, it may be used with the Tel-Instrument T-15B ATC/DME Signal Generator also.
Output of the T-16A consists of video pulse trains which modulate the signal generators previously mentioned. The unit will test DME response to simulated distances up to 310 nautical miles and
ground-speed indication up to 600 knots. This latter feature is important when testing newer equipment that includes ground-speed indicators. Output pulses are 0-10 volts into 50 ohms, with the
coded pulse-pair spacing adjustable from 3 to 39 microseconds.
The TIC Type T-16A DME Pulse Generator is a solid-state instrument that provides laboratory-quality impulses for DME checkout.
TESTING DME
The following operating characteristics are usually checked when
testing distance-measuring equipment:
Receiver sensitivity.
Transmitter power.
Decoder sensitivity.
Identification.
Distance and velocity accuracy.
Search, ranging, and memory.
Age performance.
Test equipment for DME usually consists of a special uhf signal
generator and modulator. The uhf
generator provides the rf signal, which has been changed into pulse
groups by the modulator. Together, these two instruments actually
simulate the ground station and reply to the interrogations of the
DME. One input of the oscilloscope is connected to a detector, which
is inserted into the output of the DME so that both responses can
be monitored. A known amount of attenuation is also inserted into
the DME output to reduce the transmitter output to a conveniently
measurable level.
|
![]() |
By bidding on this auction you agree to the following terms: Shipping Terms:
Payment Terms:
International Terms: (These terms only apply to international shipments.)
Warranty Terms:
Return Terms:
Medical Terms: The following terms apply to any and all medical items or any item offered for sale in any medical category or any item that deems these terms are applicable to:
If any provision of this Auction Contract is held unenforceable, All remaining provisions of this Contract shall remain in full force and effect. Copyright 2014 BetterwithBusiness - All Rights Reserved. |
Ausschreibungsinformation
Ausschreibungsart | Galerie-Ausschreibung |
Ausschreibung Nr. | 199279005 |
Startzeit | Do 21 Okt 2021 04:54:01 (CEST) |
Endzeit | Läuft-bis-verkauft |
Startgebot | Festpreis (Bieten nicht möglich) |
Artikelzustand | Kaputt/zum Ausschlachten |
Gebote | 0 |
Besucherzahl | 623 |
Versandzeit | 3 Tage |
Menge | 1 |
Ort | USA |
Automatisch verlängern | Nein |
Neueste Verkäuferbewertungen
Rückgabebestimmungen
Rücksendung akzeptiert
Refund Type:
Shipping Cost Paid by: Buyer
Returns Within: 14 Days