Lindos LA102 Audio Measuring test set Audio Analyser LA100 Series
- Condition : Used
- Dispatch : 3 Days
- Brand : Lindos
- ID# : 198973967
- Quantity : 1 item
- Views : 1977
- Location : United States
- Seller : bizsurplus (+90)
- MPN : LA102
- Start : Thu 21 Oct 2021 03:57:22 (BST)
- Close : Run Until Sold
- Remain : Run Until Sold
Other: See Description
International Shipping to United Kingdom
for 1 item(s) edit

USPS Priority Mail Intl 10lb 0oz = US$120.75 (£89.28)
US$3.50 (£2.59) handling fee included.
USPS Priority Mail Express Intl 10lb 0oz = US$138.15 (£102.15)
US$3.50 (£2.59) handling fee included.
US$3.50 (£2.59) handling fee included.
USPS Priority Mail Express Intl 10lb 0oz = US$138.15 (£102.15)
US$3.50 (£2.59) handling fee included.
Shipping Calculator
Seller's Description
Lindos LA102 Audio Measuring test set Audio Analyser LA100 Series
We gladly ship worldwide*!
| |
Lindos LA102 Audio Measuring test set Audio Analyser LA100 Series
Good working condition
Features:
Includes Power cord!
LA102 Audio Measuring Set Specifications:
Inputs10kand 600selectable. Differential inputs, with L/R selection.
Overload protection100V rms, diode limited.
Level measurement-95 to +28dBu in 10dB ranges (autoranging/manual).
DefaultRMS 2Hz-100kHz -3dB, 20Hz-40kHz -0.2dB.
Options 2-5RMS 22Hz-22kHz, VU 22Hz-22kHz, RMS A Wtd, PPM, VU A Wtd.
High pass filter400Hz with12dB/octave selectable.
Audio band filterselectable with 22Hz 12dB/octave, 22kHz 36dB/octave.
Level resolutionNumeric: 0.01dB steps. Bar graph: 0.2dB/pixel (default) 0.04dB/pixel (zoomed).
Level accuracy.05dB +28 to -60dBu, .2dB -60 to -80dBu
FrequencyReciprocal counting 20Hz-20kHz, 4-5 digit readout
Phase, 20Hz to 20kHz with accuracy (up to 40kHz with reduced resolution).
Noise measurement-105 to +8dBu in 10dB ranges.
DefaultITU-R 468 weighted quasi-peak.
Options 2,3,6,7ITU-R 468 unweighted, RMS 22-22k, ITU-R 468/ARM, ITU-R 468 RMS.
Residual Noise-97dBu ITU-R 468468 wtd, -107dBu RMS 22kHz.
Rumble measurementWeighted slow (IEC98) (on noise option 5). Unweighted slow (IEC98) (on noise option 4).
Crosstalk-117 to +8dBu, narrow band measurement, automatic freq. selection. Measured with a two stage 12dB/oct bandpass filter. -1dB at 20% frequency error, -10dB at one octave.
Options1-6100Hz, 315Hz, 1kHz, 6.3kHz, 10kHz, 40Hz. 400Hz instead of 315Hz available to order.
Options 7-980Hz-400Hz, 1.8kHz-21kHz and 12-21kHz bandpass.
Residual Noise-117dBu at 1kHz, -111dBu at 6.3kHz typical.
DistortionTHD+Noise, relative, with automatic fundamental measurement and filter frequency selection. Measured with a combined multi-stage notch and high-pass filter. Frequency tolerance is % for 70dB rejection. No nulling required and the broad notch rejects flutter sidebands effectively. (-60dB @ +2%)
Options 1-6100Hz, 315Hz (3rd harmonic), 1kHz, 6.3kHz, 10kHz, 40Hz.
Input Level Range-60dBu to +28dBu, noise limits readings below 0dBu.
Residual readingCombined specification as for LA101 above.
Response.5dB at 2nd harmonic, 22kHz 36dB/octave band-limited.
Wow & flutter-80dB to -20dB (0.01% to 10%).
Defaultweighted quasi-peak to IEC386, DIN45507.
Options 2,6,7Unweighted quasi-peak, weighted RMS, Unweighted RMS.
Quantising distortion40Hz notch, 400Hz HP, Wtd ITU-R 468 & Unwtd rms.
Difference frequency dist.70Hz bandpass filter for 2nd order difference frequency distortion measurement on double tone with 70Hz separation (1kHz-20kHz).
FIM (Frequency Intermod.)To DIN45411 (3KHz/300Hz) to -60dB, 0.1%
SequencesResponds automatically to all LA101 sequences.
FSK speed tolerance% speed error allowed.
Monitor loudspeakerWith volume setting and listen switch.
Scope/headphones outputBNC 1V RMS output mid-scale and 0/+5V BNC sync. pulse.
22Hz-22kHz filterElliptic design with 60dB rejection at 44kHz. This permits valid distortion measurement on digital equipment despite sampling residue.
Sequence resultsSweeps produce a graph on the display with cursor readout, automatic scrolling and scaling facilities. Sequences produce a graph plus several pages of data with quick access.
PrintoutSequence results can be printed directly on an Epson ESC/P, IBM or HP Deskjet compatible printer fitted with serial interface. Printout includes high resolution frequency response graphs.
Sequence results memories5 sequence memories allow later printout or analysis.
Tolerance testing5 user programmable tolerances in addition to 10 pre-programmed tolerances (Selftest, IBA, EPS81, EPS84, EPS98, Studer A812 etc)
Test tape modeLA102 can automatically measure frequency response, W&F and speed from a test tape, ignoring voice announcements and plotting an interpolated graph between the spot frequencies it finds. External frequency sweeps can also be used.
Don't forget to place your bid.
|
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
By bidding on this auction you agree to the following terms:
Shipping Terms:
Payment Terms:
International Terms: (These terms only apply to international shipments.)
Warranty Terms:
Return Terms:
Shipping Damage Terms:
Medical Equipment Terms:
The sale of these items may be subject to regulations by the U.S. FDA and state and local regulatory agencies. If so, you may not be able to bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. Seller: Daniel Rydell San Diego, CA contact via messages.
If any provision of this Auction Contract is held unenforceable, All remaining provisions of this Contract shall remain in full force and effect.
Copyright 2017 BigonBusiness - All Rights Reserved.
|
Listing Information
Listing Type | Gallery Listing |
Listing ID# | 198973967 |
Start Time | Thu 21 Oct 2021 03:57:22 (BST) |
Close Time | Run Until Sold |
Starting Bid | Fixed Price (no bidding) |
Item Condition | Used |
Bids | 0 |
Views | 1977 |
Dispatch Time | 3 Days |
Quantity | 1 |
Location | United States |
Auto Extend | No |
Seller Recent Feedback
Returns Policy
Returns Accepted
Refund Type: Money Back
Shipping Cost Paid by: Buyer
Returns Within: 30 Days