Bruel & Kjaer type 2007 Heterodyne RF Selective Voltmeter 100 kHz to 305 MHz
- Condition : Not Working or Parts
- Dispatch : 3 Days
- Brand : Bruel Kjaer
- ID# : 199279537
- Quantity : 1 item
- Views : 1276
- Location : United States
- Seller : bizsurplus (+90)
- MPN : 2007
- Start : Thu 21 Oct 2021 03:52:22 (BST)
- Close : Run Until Sold
- Remain : Run Until Sold
Other: See Description
International Shipping to United Kingdom
for 1 item(s) edit

USPS Priority Mail Intl 29lb 0oz = US$220.60 (£167.28)
US$8.50 (£6.45) handling fee included.
USPS Priority Mail Express Intl 29lb 0oz = US$240.05 (£182.03)
US$8.50 (£6.45) handling fee included.
US$8.50 (£6.45) handling fee included.
USPS Priority Mail Express Intl 29lb 0oz = US$240.05 (£182.03)
US$8.50 (£6.45) handling fee included.
Shipping Calculator
More Listings from This Seller view all
Seller's Description
Bruel & Kjaer type 2007 Heterodyne RF Selective Voltmeter 100 kHz to 305 MHz
We gladly ship Worldwide*
Scroll down for more Photos and details
|
Bruel & Kjaer Heterodyne Voltmeter Type 2007
operates on 100-240v AC
The Bruel Kjaer 2007 Heterodyne Voltmeter is a completely self-contained, precision instrument designed to measure directly voltages in AM-FM, single sideband(SSB), and television (TV)frequency angles. It will determine the voltage level, the frequency, and the modulation percentage of an input signal. The instrument can be powered from AC main. The Heterodyne Voltmeter Type 2007 is developed from the Type 2006. Type 2007 is equipped with electronic control of the variable oscillator, and the frequency range is 100 kHz to 305 MHz in eight overlapping ranges. The tuned frequency is indicated on a moving coil meter provided with interchangeable scales. Three scales are included, a general frequency scale, a scale for American TV channels, and one for European TV channels. Scales can be custom made to order. The Heterodyne Voltmeter Type 2007 has been designed with an untuned input and a mixer circuit with an ultra flat frequency response. ith the normal type of instrument having a tunable input, recalibration is necessary at each frequency due to the corresponding "Q" changes. However, the B & K Type 2007 establishes self-calibration from a built-in stabilized 27 MHz reference oscillator. After calibration, further adjustments are not necessary while sweeping the entire frequency range from 100 kHz to 305 kHz. The input probe contains a high impedance FET stage providing minimum load of the ircuit being measured. The normal voltage measuring range covers 100UV to 100 mV ull scale deflection. The built-in attenuator provides seven accurate 10 dB steps in sensitivity.
A 60 dB attenuator (not included) can be attached which, when fitted to the input probe port, extends the range to 100 V. In the six higher frequency ranges covering 7 to 305 MHz a triple-detection receiver is used providing double conversion. This design gives more than 50 dB image-frequency and ntermediate frequency rejection also in these ranges. A crystal filter following the mixer stage provides a "narrow" measurement bandwidth of 1.25 kHz. By switching out this filter a wide" bandwidth of kHz is obtained. Option available for odification to fulfil the CISPR requirements. The eterodyne Voltmeter ha a versatile readout ystem, featuring four major output indicators: a ual function meter for voltage level and modulation, the frequency indication meter, and a built-in loudspeaker for signal identification. A peak etector is built-in for TV measurements.
Don't forget to place your bid.
More photos down below
|
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
By bidding on this auction you agree to the following terms:
Shipping Terms:
Payment Terms:
International Terms: (These terms only apply to international shipments.)
Warranty Terms:
Return Terms:
Medical Device Terms:
The following terms apply to any and all medical items or any item offered for sale in any medical category or any item that deems these terms are applicable to:
Item Condition Terms:
On these listings, our company's condition "used" does NOT necessarily mean "fully operational and functions as intended". If fact it may have unknown flaws and deficiencies. the item has only been tested to the extent described in the item condition/testing notes. Additional testing may be performed upon request of the buyer before shipment to ensure a satisfactory transaction for both parties.
If any provision of this Auction Contract is held unenforceable, All remaining provisions of this Contract shall remain in full force and effect.
Copyright 2018 betterwithbusiness- All Rights Reserved.
|
Listing Information
Listing Type | Gallery Listing |
Listing ID# | 199279537 |
Start Time | Thu 21 Oct 2021 03:52:22 (BST) |
Close Time | Run Until Sold |
Starting Bid | Fixed Price (no bidding) |
Item Condition | Not Working or Parts |
Bids | 0 |
Views | 1276 |
Dispatch Time | 3 Days |
Quantity | 1 |
Location | United States |
Auto Extend | No |
Seller Recent Feedback
Returns Policy
Returns Accepted
Refund Type: Money Back
Shipping Cost Paid by: Buyer
Returns Within: 14 Days