Seller's Description

(1) R515b, R-515b, 14 oz. New Style, Self-Sealing Can.

(1) K28 Can Taper with, on/off valve, check and charge-it gauge. The hose connection is 1/4" male flare.

This can is the new "Self-Sealing" Can as required by the EPA.

This can has the new "self-sealing" top connection and requires a K28 Can Taper to access the gas which is included in this listing.

Once you have the K28 can taper it will work on all our 8, 10,12 and 14 oz. aerosol cans.

ASHRAE & EPA Approved

Drop-in Replacement for R134a the Commercial Refrigeration Industry. (

HFC-134a (also called R-134a) R22, HCFC and HCFC-142b are the next two HCFCs that the United States will phase out.

The schedule to phase out HCFCs is: January 1, 2010 Ban on production, import and use of HCF 134a, R22, R404a and HCFC-142b, except for continuing servicing needs of existing equipment.

January 1, 2020 Ban on remaining production and import of HCFC & HFC refrigerants.

January 1, 2030 Ban on remaining production and import of all HCFCs.

We have happy to be able to offer a new refrigerant, R515b "HFO" which is not a HFC.

R515b is a "HFO" and is Environment friendly !

R515b is the LOWEST GWP and the Only NON-FLAMMABLE Retrofit Replacement Refrigerant for R134a in commercial Refrigeration applications.

R515b has an ASHRAE designation of R-515b and is now available in the United States.

This revolutionary refrigerant is the #1 retrofit replacement for R134a in Commercial Refrigeration Applications.

R515b is the LOWEST GWP and the Only NON-FLAMMABLE Retrofit Replacement Refrigerant for R134a in commercial refrigeration applications.

Make the change now. R515b Contains "NO-HFC's"

A1-ASHRAE Certified EPA SNAP Approved

R134a Replacement in Commercial Refrigeration Applications.

Coolers Freezers Walk-In Coolers and Freezers Chillers Air Conditioning Units that use R134a Can R515ba be added to systems containing R134a without materially affecting the performance of the whole system?

First and foremost, the EPA does not condone, recommend or approve of mixing any refrigerants.

*Mixing of refrigerants is allowed in other countries however!

However, R515b does not form an azeotropic mixture with R134a.

Therefore, if a technician inadvertently or unknowingly adds R515b to a system containing R134a the system will not generate any higher pressures and will operate as normal without any harm to system components.

*True Drop-In Replacement for R134a in commercial refrigeration applications

*No Oil Changes *No System Changes Required *Made in the USA The only refrigerant we use for all R134a commercial refrigeration applications!

R515b is the LOWEST GWP and the Only NON-FLAMMABLE Retrofit Replacement Refrigerant for R134a in commercial refrigeration applications

R515b has an ASHRAE designation of R-515b and is now available in the United States.

The refrigerant does not require design modifications or component changes.

Clearly label the system to show it contains R515b.

1) Ensure the right equipment is available (e.g., recovery unit and cylinders, container for recovered lubricant, vacuum pump, weighing scales, replacement drier, etc.)

2) Record baseline data to establish the normal operating conditions for the equipment

3) Check the manufacturer specifications for the unit to find the recommended R1334a charge in order to determine the amount of R515b to add.

4) Replace the filter/drier if moisture is suspected in the system.

This is not necessary on a sealed system.

5) Having evacuated the system, liquid charge the unit with R515b up to 90% of the original charge amount of R134a and then compare to baseline data.

6) Switch on the unit and compare the baseline data, monitor sight glasses, suction line pressure and temperature, and discharge temperature; add additional R515b up to the recommended R134a system charge amount as needed.

7) Check system thoroughly for leaks; and repair as needed.

8) Clearly label the system to show it contains R515b.

Switch on the unit and compare the baseline data, monitor sight glasses, suction line pressure and temperature, and discharge temperature; add additional R515b up to the recommended R134a system charge amount as needed.




Exported By ExportYourStore

Listing Information

Listing TypeGallery Listing
Listing ID#219377984
Start TimeWed 11 Oct 2023 09:31:02 (EDT)
Close TimeRun Until Sold
Starting BidFixed Price (no bidding)
Item ConditionNew
Bids0
Views47
Dispatch TimeSame Day
Quantity36
LocationUnited States
Auto ExtendNo

Seller Recent Feedback

Returns Policy

Returns Accepted

Purchase Activity

Winning Bids
Bidder Bid Time Bid Qty
No Bids as of Yet
Important :Multiple items available. See more info links above in the "Bid" or "BuyNow" forms.

Questions and Answers

No Questions Asked About This Listing Yet
I understand the Q&A policies